Soundcare superspikes M6 101 spikes
search
  • Soundcare superspikes M6 101 spikes
  • Soundcare superspikes M6 101 spikes
  • Soundcare superspikes M6 101 spikes

Soundcare High-End superspikes 1/4 305 spikes

305E
167,60 € Maksudeta
204.47 € tax incl. for EU buyers

Soundcare High-End superspikes 1/4 305 spikes, pack of 4pcs

Kogus
Toodete saadavus tellimisel

Soundcare High-End superspikes 1/4 305 spikes, pack of 4pcs

Soundcare® SuperSpike High-End models: The High-End SuperSpikes are very exclusive spike made for people that want something special. The High-End SuperSpike is hand made in Norway. The zinc parts are covered with layers of copper, chrome and a golden layer. The plastic housing is made of clear polycarbonate. The Soundcare® High-End SuperSpike is a jewel to your equipment. Must be seen!!!

Both standard High-End models are available in four threaded versions, M6, M8, 1/4 inch and 5/16 inch and in a self adhesive version. In addition you can also convert M6 to M10 and 1/4” to 3/8” with our threadconverters.

You can find the threadsize you need in the THREADSIZE TABLE

How it is designed

All Soundcare® spikes are spikes with a rounded tip (0,5 mm in diameter) standing in a crater with

a flat bottom. In this way we get a very small contact area combined with enormous strength.

Load tolerances is only of theoretical interests. For standard spikes you can put 400 kg per spike,

for the TITANIUM models even more.

The Soundcare SuperSpike is an assembly of :

An outer, sturdy, clean looking housing of ABS plastic (standard version) or polycarbonate (High-End version) (1).

Spike made of first class case hardened steel (2).

Zinc casing (3) that reduces resonances in the spike and is specially designed to hold the plastic housing when the equipment is lifted.

Zinc disc (4) with a mild steel insert (5).

Self adhesive felt disc made from 1,25mm quality felt with permanent fairly high coatweight tape.

Double coated tape, 3M 9573 high performance permanent tape (only the self adhesive version).

Lock nut. (only the threaded versions).

      

The Measurement

         

Measurements for Soundcare SuperSpikes:

A calibrated loudspeaker has been fed with a sinus wave on each frequency level. The loudspeaker has been placed upon a calibrated pressure sensitive microphone. For each frequency the signal is fed through the loudspeaker and the output level is adjusted to specific level which is referred to as 0 dB. Then the spike is placed between the loudspeaker cabinet and the pressure sensitive microphone. The same signal with the same output level is used. The level from the microphone is then measured. The direct sound through air from the loudspeaker to the microphone is never measured louder than –30 dB for any of the frequencies. The curves will therefore show the approximate transmission of energy from loudspeaker cabinet through the spike and down to the microphone.

In words the damping of acoustic feedback is:

50 Hz      -11 dB
100 Hz     -10 dB
150 Hz    -6 dB
200 Hz    -1 dB
300 Hz    -6 dB
400 Hz    -3 dB
600 Hz   -3 dB
800 Hz   -1 dB
1600 Hz   0 dB
2500 Hz   0 dB
3200 Hz  -5 dB
6400 Hz  -2 dB
9600 Hz      -2.5 dB
12800 Hz      -3 dB

We do not know of any other that has measured spikes this way before. Until now spikes only have been listening tested as far as we know. This is a way to try to measure the benefits in a way that makes it possible to show the results on paper. There can be inaccuracy because of unknown resonances and other unknown influence, but we are sure these results show how spikes reduce acoustic feedback.

The influence of reducing the feedback at one frequency for another is not measured. Listening tests show that reducing feedback at low frequencies does have large influence on the sound quality at higher frequencies. The different models, threaded and self-adhesive have been tested. The results are so similar for the different models that it does not influence the curve. At 50Hz (the most important frequency to damp) we had a reduction of 11 dB, which means that appr. 95% of the feedback energy was stopped.

305E
Kommentaarid (0)
Hetkel pole ühtegi ülevaadet