Lundahl Isolation transformer, LL1570
search
  • Lundahl Isolation transformer, LL1570

Lundahl Isolation transformer, LL1570

LL1570
67,74 € Без НДС
82.64 € с НДС для покупателей из ЕС
Lundahl Isolation transformer, LL1570
Количество
В наличии

Transformers for splitting LL1570

The LL1570 is designed for splitting signals in application where large ground differences may appear, but is also very useful as a general purpose audio transformer. By careful design, the capacative coupling between the different part of the transformer is kept to a minimum. The three-section winding structure which is necessary for decoupling also results in a very high bandwidth. The transformer is built up from two coils, each with primary and secondary windings separated by electrostatic shields, and a high permeability mu-metal core. The two coil structure in combination with the mu-metal can results in high immunity to external magnetic fields.

In the LL1570XL, the core is about 45% larger than in the LL1570, resulting in a larger level capability.

Turns ratio: 1 + 1 : 1 + 1

Spacing between pins: 5.08 mm (0.2")
Spacing between rows of pins: 27.94 mm (1.1")
Offset of earth pin from adjacent row: 2.54 mm (0.1")
Recommended PCB hole diameter: 1.5 mm

LL1570

LL1570XL

Dimensions (Max. L x W x H above PCB(mm)):

38 x 24 x 17

38 x 24 x 20.5

Weight:

48 g

65 g

Static resistance of each primary:

50 ?

62 ?

Static resistance of each secondary:

50 ?

62 ?

Distortion (primary level, primaries connected 0.1% @ + 6 dBU, 50 Hz 0.1% @ + 9 dBU, 50 Hz in series, source impedance 800?):

0.1% @ + 6 dBU, 50 Hz

1 % < @ +16 dBU, 50 Hz

0.1% @ + 9 dBU, 50 Hz

1 % < @ +19 dBU, 50 Hz

Self resonance point :

> 250 kHz

> 250 kHz

Optimum load for best square-wave response (secondaries. in series):

2.8 k? in series with 0.7 nF

2.8 k? in series with 0.7 nF

Frequency response (source 600?, load as above, serial-serial connections):

10 Hz -- 200 kHz +/- 0.5 dB

10 Hz -- 200 kHz +/- 0.5 dB

Isolation winding-winding / winding-shield / shield-shield:

4 kV / 2 kV / 2 kV

4 kV / 2 kV / 2 kV

LL1570
Комментарии (0)